Spartan preconfigured enclosures ship completely assembled and offer a high quality, cost effective solution for mounting your IT components. With integrated cable management, split side panels and 70% perforated doors, AMCO’s Spartan cabinets are a great solution for stand-alone cabinets or for large data center deployments.

Certified Load Ratings:

Static: 3,000 lbs.

Features:

  • Shipping in 1-2 business days
  • Sizes:
    • 47U, 86.61″ Height, 31.50″ Width, 50.00″ Depth
    • 47U, 86.61″ Height, 23.62″ Width, 50.00″ Depth
    • 47U, 86.61″ Height, 23.62″ Width, 42.12″ Depth
    • 42U, 78.74″ Height, 23.62″ Width, 50.00″ Depth
    • 42U, 78.74″ Height, 23.62″ Width, 42.12″ Depth

Includes:

  • Doors
  • Side panels
  • Top panel
  • Baseplate
  • Casters and levelers
  • Power panels
  • Ground straps and ground studs
  • Full range of additional accessories
  • Static: 3,000 lbs.
  • Durable powder coat finish
  • ROHS Compliant
  • ISO9001 Certified
  • 5-Year Warranty

Design your rack on our Configurator for a quote, 3-D model, and techincal specifications.

Configurator
Find Your Sales Representative
Order Support

Mounting Channels:

Mounting Channels

Mounting channels are capable of moving completely forward or backward within the rack to provide precise equipment adjustments. Mounting channels feature an M6 square-hole pattern and have individually numbered RUs for each rack unit, resulting in fast and easy equipment installation. All Spartan mounting channels have a durable black powder coat finish.

MCX Profile Features For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

For standard 19″ mounting on 24″ overall rack widths (24″ width frames require two pairs of MCX mounting channels per frame)

MCW Profile Reducer Features For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

  • Provides 19″ front-mounting space in a 29″ overall rack width
  • Cable egress included with edge guard and cover
MCL1 Profile Reducer 1RU Device Features For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

 

  • Provides 19″ front-mounting space in a 29″ overall rack width
  • 1.75″ high by 17″ cutouts for 1RU equipment mounting, resulting in additional rack space
MCW Profile Reducer Finger Channel Features For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

 

  • Provides 19″ front-mounting space in a 29″ overall rack width
  • 1RU or 2RU wire finger managers provide cable management support to individual RUs in rack
  • Metal fingers have a depth of 9.25″ to accommodate larger cable bundles

Panels:

Side Panels

Spartan side panels are split to accommodate easy removal and installation. The side panels also feature a spring latch and lock as well as a ground stud on the interior.

Side Panel
 
Top Panels

Top panels include a brushed cable egress port in each corner making cable entry and exit fast and simple.

Top Panel
Duel Brush Strip

Doors:

Face Doors

Curved front door adds a contemporary look and is 70% open. The curved door is 2” in depth. The front door can be right or left hinged.

Curved-Face Vented Door For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)
French Doors

French rear doors are 70% open, feature a 2 point latch, allow easy access to equipment and cabling and are 1.5” in depth.

Vented French Door For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)
Vented French Door with Solid Insert For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

Shelves and Drawers:

Shelves

Heavy duty shelves are 1.75″H (1RU), fit 19″ width panel openings, and have depths of 17″ up to 40″. They are available in solid or vented models and are load-rated to support up to 250 lbs. Shelves mount to the front and rear of the mounting channels.

UA Series shelves are light duty and mount to the front of the mounting channel. The shelves are 19″ wide, 18″ deep, and available in the following heights: 1RU, 2RU, 3RU, 4RU and 5RU.

Solid Heavy Duty Shelf For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)
Vented Heavy Duty Shelf For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)
Vented Light Duty Shelf For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)
Drawers

UA Series drawers are perfect for applications that require a lockable, light-weight storage soution. They are 19″ wide, 18″ deep, feature a keyed lock, and mount to the front of the mounting channels. Drawers are available in heights of 2RU, 3RU, and 4RU.

Heavy Duty Drawer For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

Cable Management:

Vertical

Available in five rack heights and two widths, power/cable panels mount in the rear of the rack and provide mounting support for PDUs and cable bundles. Power/cable panels have a combination of keyhole pattern slots, M6 square holes and cable egress ports. Cable lacing strips have a combination of M6 holes for cable ring mounting (HK-CR1) or equipment tie-down, while the slots can accept cable ties, fasteners, etc.

Vertical Cable Management Features

  • Tool-less mounting makes PDUs mounting fast and easy
  • Frees up additional RU space in a rack as PDUs are mounted to the panel rather than in the panel opening
  • Properly organized cabling and PDUs at the rear of the rack do not block hot air exhausted from the back of servers. Hot, trapped air increases back pressure and results in higher thermal loads
  • Panels are an efficient cable management solution that neatly organizes your cable bundles
 
Cable Lacing Strip For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)
Cable Ring Kit For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

 

Cable rings easily mount to M6 holes in power/cable panels or cable lacing strips and provide an immediate tie-down point for cabling. Sold in packs of 5.

Horizontal

Horizontal Cable Management

  • 2RU panel height (3.50”)
  • 10 ga. steel construction
  • Available in 4” and 7” depths
HCM4 – 4” Depth HCM7- 7” Depth For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

 

Cable Raceways

TitanDT offers cable raceways for large bundle drops of cabling or power strip mounting between racks. It takes 0RU, organizes cable and power requirements neatly and works against heat buildup that blocks exhausted air at the rear of the rack.

Cable Raceway Kit For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

  • Create your choice of 6, 8, 10* or 12* width openings between racks for cable management
  • Includes choice of solid or vented front door, back panel and choice of 1RU or 2RU fingers that are 9.25 deep
Cable Raceway Kit Without Back Panel For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

  • Same sizing options and components as above, except back panel is not included
  • Includes choice of solid or vented front door and choice of 1RU or 2RU fingers that are 9.25 deep
Cable Raceway Doors For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

  • Same sizing as above cable raceway kits
  • Available in solid or vented, providing easy access to cabling between two racks
Spacer Panel For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

  • Sized as all components above
  • Creates space between racks that requires no access to the cabling
Back Panel For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

  • Sized same as components above
  • Used for cable management or power strip mounting between racks
  • Note: Also offered with 1RU or 2RU fingers

Other Accessories:

Power

Power panels are 4.5” in depth and allow for tool-less mounting of PDU’s and can also be used for vertical cable management.

Power Panel
6RU Tool-less Blanking Panel - Plastic

Blanking Panel Features

  • Tool-less
  • Cover empty spaces in panel openings
  • Optimize air circulation
For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)
For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)
For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)
For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)
For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)
Tool-less Blanking Panel - Steel

Lower your TCO while increasing your racks energy efficiency. Help control airflow in your rack by blocking off open RU spaces using blanking panels. Amco Tool-less blanking panels are available in steel 1RU thru 8RU – rack unit heights.

Blanking Panel Features

  • Tool-less
  • Cover empty spaces in panel openings
  • Optimize air circulation
Blanking Panel – Steel For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)
Blanking Panel – Steel For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)
Blanking Panel – Steel For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)
Blanking Panel – Steel For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)
Also available in Aluminum For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

Formed blanking panels are aluminum and also available individually or in kits. *Not available in tool-less.

Casters/Levelers

Spartan cabinets come standard with casters for easy deployment. Heavy duty levelers are also included.

  • Light duty -175 lbs. load rating
  • Heavy duty -1,200 lbs. load rating
Light Duty Caster For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

 

175 lbs. load rating

Heavy Duty Caster For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

 

1,200 lbs. load rating

Hardware Kits

Each rack ships with 50 ea. Dzus M6 inserts and screws to make mounting hardware/components easy to install. Additional mounting hardware is available for equipment mounting.

M6 Hardware For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)

 

 

HKM6-25 or 50: M6 hardware includes 25 or 50 screws for equipment mounting.

Dzus M6 Hardware For standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)HKDZ-25 or 50: M6 Metric Dzus includes 25 or 50 easy inserts and M6 clear chromate screws.
Joining Kit

Spartan racks join together on the front and rear of the frame using a simple bracket and bolt that are included with the frame.

Joining Hardware
Frame Joining KitFor standard 19" mounting on 24" overall rack widths (24" width frames require two pairs of MCX mounting channels per frame)
Cable Ring Kit

HK-CR1: Includes bag of 10 pieces.

10-32 Hardware Kit

 
10-32 Hardware Kit

10-32 Hardware Kit

HKEP1032-25

 

GET IN TOUCH WITH US TODAY